PRODUCT SPECIFICATIONS
Inputs
12 -24VDC, 300 mA (Power), AC/DC Converter
Flow Rate Input: 0-8 Volts Minimum (24 Volts Max)
One of the Following:
• 2 Pressure Transducers: 4 -20 mA
• 1 Differential Pressure Transducer: 4 -20 mA
Deadman Switching Relay
3A @250 VAC Max
Visual Outputs/Indicators
Interactive Touch Screen
Daylight Readable
Optional Amber Light: Warning Indicator
Optional Red Light: Critical Indicator
Corrected Differential Pressure
Actual Differential Pressure
Flow Rate
Peak Corrected and Actual Differential Pressure
Real-Time Corrected Differential Pressure Charting
Sudden DP Rise or Drop Alarm
Data Logging
Removable Micro SD Card (Included)
>36 Months Data (MS Excel Compatible)
60 Second Logging Interval (User Configurable)
Data Download via USB (Optional)
Data Outputs
RS232 (ASCII Serial Data Stream)
Measurement Units
PSI, USGPM
BAR, LPM
Alarm triggers
Warning Alarms (Amber Light)
• 12 PSI or 0.8 BAR (User Configurable)
• Pressure Greater than the System Rating
• Change in DP (User Configurable)
Critical Alarms (Red Light)
• External Switch Relay (Deadman)
• 15 PSI or 1.0 BAR (User Configurable)
• Change in DP (User Configurable)
Weight
4 pounds (1.8 kg)
Safety/Compliance
IP 65
NEMA 4X
ATEX Directive Class 1 Zone 2 Group D
PRODUCT OPTIONS
Pressure Sensors
2x Pressure Transducers - Class I Division I
1x Differential Pressure Transducers - Class I Division I
1x Differential Pressure Transducers - IP65 NEMA 4
|