Velcon Filters, Inc.
Velcon Filters, Inc.

 
Contact Velcon:
Phone:
719.531.5855
800.531.0180
Fax:
719.531.5690
Mailing Address:
Velcon Filters, LLC
1210 Garden of the Gods Road
Colorado Springs, CO 80907
Email:
vfsales@velcon.com

 

     
 

Aquacon® Cartridges

 
 
Velcon Aquacon Cartridges

Water absorbing "monitor" cartridges


  • Filter particulate matter and absorb water with great efficiency

  • Water capacity is ~40 x greater than 2” diameter monitor cartridges

  • Also provide protection against water slugs.

Outside-to-In Flow Datasheet PDF (85 KB)

Inside-to-Out Flow Datasheet PDF (82 KB)

 

ACO Series - Outside-to-In Flow Cartridges

Remove Water and Dirt from Jet Fuel and Avgas


  • Free and emulsified water to less than 5 ppm
  • 1/2 micrometer particulate removal
  • Provides protection against “slugs” of water
  • Pressure increase signals cartridge change
  • Use with existing filter housings
Velcon Aquacon Cartridges

 

Velcon Aquacon Cartridges

DESCRIPTION

Patented Aquacon® Filter Cartridges have a unique high-capacity inner filter media which removes all free and emulsified water from hydrocarbon fuels down to less than 5 ppm in the effluent. Absorbed water is chemically locked into this media.

When a cartridge reaches its water holding capacity, its accordion pleats swell and cause an increase in the differential pressure which signals the operator to change the cartridge.

Solid contaminants are removed by the cartridge’s two particulate filter media layers. The pleated accordion style design provides a large surface area for maximum dirt holding capacity. Models are offered for particulate filtration down to 1/2 micrometer size with 98% plus efficiency. Performance is not affected by the presence of common surface active agents.

Compact Aquacon® Cartridges are quick and easy to install. Models are available to fit most existing standard housings. Refer to Cartridge Selection Table on below.

 

*****CAUTION*****
DO NOT USE WITH PRE-MIXED FUELS CONTAINING
ANTI-ICING ADDITIVES.

 

Use form 1846 for cartridge change out at flowrates less than rated flow.

 

CARTRIDGE SELECTION TABLE

 

Model

Number

Micron

Ratings

Inside

Diameter

(Inches)

Outside

Diameter

(Inches)

Length

(Inches)

Collapse

Pressure

(psi)

Maximum

Flow Rate

(USGPM)

Interchange

Information

ACO-21001L 0.5 1 1/32 2 5/8 9 3/4 60 15 Fits VF-31E Housing
ACO-31001L 0.5 1 5/16 3 9 3/4 75 20 Fits Purolator Vessel PR-172-3
ACO-40501SPL 0.5 1-12NF 3 3/4 5 1/2 60 10 Use with head SPH-2
ACO-40801L 0.5 1 3/4 4 8 100 13 Rellumit Replacement
ACO-40901SPL 0.5 1 3/8 -12NF 3 3/4 8 1/2 60 15 Use with head SPH-3
ACO-41201L 0.5 1 3/4 4 12 1/4 100 20 Replaces Facet C-707;
Purolator Vessel PAG-50
ACO-41601L 0.5 1 3/4 4 15 13/16 100 27 Rellumit Replacement
ACO-41801L 0.5 1 3/4 4 18 100 30 Replaces Facet C-706 and
Keene BP-419, BP-518
ACO-41901L 0.5 1 3/4 4 19 7/8 175 32 Rellumit Replacement
ACO-51201L 0.5 1 7/8 5 5/8 12 1/4 75 50 Fits VF-61 Housing
ACO-512P3L 0.3 1 7/8 5 5/8 12 1/4 75 50 Fits VF-61 Housing
ACO-60801L 0.5 3 1/2 6 8 1/4 100 30 Omeco 6” x 8” Replacement
ACO-60901L 0.5 1 1/2 6 9 11/16 100 36 Fits Fram/Facet VFCS-21
(Element CC-21-7); VF-609
ACO-609P3L 0.3 1 1/2 6 9 9/16 100 36 Fits Fram/Facet VFCS-21
(Element CC-21-7); VF-609
ACO-61201L 0.5 1 1/2 6 13 3/4 100 48 Fits Fram/Facet VFCS-22
(Element CC-22-7)
ACO-61401L 0.5 3 1/2 6 14 1/2 175 58 Qualified to EI 1583
ACO-62201LTB 0.5 3 1/2 6 22 175 88 Qualified to EI 1583
ACO-62901L 0.5 3 1/2 6 28 3/4 175 115 Qualified to EI 1583
ACO-63301L 0.5 3 1/2 6 33 1/4 175 133 Qualified to EI 1583
ACO-64401L 0.5 3 1/2 6 43 1/4 175 173 Qualified to EI 1583
ACO-64401LTB 0.5 3 1/2 6 44 175 176 Qualified to EI 1583
ACO-71801L 0.5 2 1/2 6 1/4 18 75 65 Fits VF-71E Housing

 

NOTE: 0.5 micron rated Aquacon® Cartridges are recommended for use with jet fuel and avgas. Effluent fuel quality meets requirements for EI 1583.

 

TECHNICAL INFORMATION

  1. Maximum operating temperature is 160°F
  2. Micron ratings are nominal at 98%+ efficiency
  3. Aquacon® Cartridges can significantly reduce flow when loaded with water or dirt. Appropriate precautions should be taken in applications where fuel flow must be maintained or where surge conditions can occur.
  4. Replace the cartridge if the differential pressure exceeds 25 psid. For service life information, please refer to Operating Procedure #1839 or consult your company fuel handling procedures.
  5. Typical water holding capacity for ACO-61401L is 700 ml.

 

 


 

ACI Series - Inside-to-Out Flow Cartridges

Velcon Aquacon Cartridges

 

Remove Water and Dirt From Jet Fuel and Avgas

  • 1/2 micrometer particulate removal
  • Provide protection against “slugs” of water
  • Pressure increase signals cartridge change
  • Replace existing coalescers in into-plane filter/separator vessels
  • Inside-to-out flow pattern

 

DESCRIPTION

Patented Aquacon® Filter Cartridges have a unique high-capacity inner filter media which removes all free and emulsified water from hydrocarbon fuels down to less than 5 ppm in the effluent. Absorbed water is chemically locked into this media.

When a cartridge reaches its water holding capacity, its accordion pleats swell, and cause an increase in the differential pressure which signals the operator to change the cartridge.

Solid contaminants are removed by the cartridge’s two particulate filter media layers. The pleated accordion style design provides a large surface area for maximum dirt holding capacity. Performance is not affected by the presence of surface active agents.

The Velcon ACI open-end and threaded-base Aquacon® Cartridges have been qualified to EI-1583, the “Energy Institute Specifications and Qualification Procedures for Aviation Fuel Filter Monitors with Absorbent Type Elements.”

The ACI-6xx01L open-end and ACI-6xx01LTB threaded base Aquacon® elements are intended to be installed in the final filter/separator vessel in place of coalescers for more protection against dirt and water downstream.

 

 

 

*****CAUTION*****
DO NOT USE WITH PRE-MIXED FUELS CONTAINING
ANTI-ICING ADDITIVES.

 

CARTRIDGE SELECTION TABLE

 

Model

Number

O. D.

(Inches)

Length

(Inches)1

End-Cap

Type

Maximum

Flow Rate

(USGPM)

Interchange

Information

ACI-61401L
6
14 1/2
3 1/2” ID Open-Ends
58
CC-N18, CA14-3, CA14-9
ACI-61401LTB
6
14
Screw Base/Blind
56
CC-N18SB, CA14-3SB, CA14-9SB
ACI-62201L
6
22 1/4
3 1/2” ID Open-Ends
89
CC-K2, CC-K28, CA22-3, CA22-9
ACI-62201LTB
6
22
Screw Base/Blind
88
CC-K28SB, CA22-3SB, CA22-9SB
ACI-62901L
6
28 3/4
3 1/2” ID Open-Ends
115
CC-N28, CA28-3, CA28-9
ACI-62901LTB
6
27 15/16
Screw Base/Blind
111
CC-N28SB, CA28-3SB, CA28-9SB
ACI-63301L
6
33 1/4
3 1/2” ID Open-Ends
133
CC-K38, CA33-3, CA33-9
ACI-63301LTB
6
33
Screw Base/Blind
132
CC-K38SB, CA33-3SB, CA33-9SB Has NSN: 4330-01-439-2314
ACI-63301FL
6
33 3/8
2” ID Open-Ends
133
Faudi F. 1-842 (1.066.020)
ACI-63801L
6
38 1/4
3 1/2” ID Open-Ends
153
CC-K38-1, CA38-3, CA38-9
ACI-63801LTB
6
38
Screw Base/Blind
152
CC-K38SB-1, CA38-3SB, CA38-9SB
ACI-64401L
6
43 1/4
3 1/2” ID Open-Ends
173
CC-N38, CA43-3 CA43-9
ACI-64401LTB
6
44
Screw Base/Blind
176
CC-N38SB, CA43-3SB, CA43-9SB
ACI-65601L
6
57
3 1/2” ID Open-Ends
228
CC-N48, CA56-3, CA56-9
ACI-65601LTB
6
56 1/16
Screw Base/Blind
224
CC-N48SB, CA56-3SB, CA56-9SB

 

1Overall length does not include the 1” bolt for the ACI-6xx01LTB threaded base ACI’s.

Note: Drain vessels equipped with the ACI Aquacon® Cartridges on a daily basis from an upstream drain to ensure upstream water is removed to prolong element life.

 

TECHNICAL INFORMATION

  1. Maximum exposure temperature is 160°F.
  2. Cartridges are rated at 1/2 micron nominal efficiency.
  3. Aquacon® Cartridges can significantly reduce flow when loaded with water or dirt. Appropriate precautions should be taken in applications where fuel flow must be maintained or where surge conditions can occur.
  4. Replace the cartridge if the differential pressure exceeds 25 psid. For service life information, please refer to Operating Procedure #1839 or consult your company fuel handling procedures.
  5. ACI burst strength exceeds 175 psid. If F/S vessel coalescer deckplate or manifold is not certified to 15 bar (220 psi) strength, a differential pressure limiting device, set from 25 - 30 psid, should be installed on the filter/separator vessel.
  6. Typical water holding capacity for ACI-61401L is 900ml.