Filter Sizing Information
AC and AD Series Aquacon® Cartridges

 
 

FILTER SIZING INFORMATION

 

  1. Select the desired filter cartridge type and micron rating.
  2. Determine the viscosity at the operating temperature for the fluid being filtered.
    See Oil Viscosity Characteristics - Data Sheet #1533.
  3. From the cartridge flow rate data, estimate the flow rate that will result in a 2 psi differential pressure.
  4. Divide the total desired flow rate by the flow rate determined in 3, above. This will give the required number of cartridges.
  5. Select a filter housing that will hold the required number of cartridges.


NOTES:

  • The recommended maximum flow rate can be exceeded by as much as 50% for “fuse-monitor” type applications with fuels and other low viscosity fluids. However, water holding capacity will be reduced and pressure losses from the filter housing itself may become excessive.
  • For higher viscosity fluids, a 5 psi differential pressure is frequently used for cartridge selection. This is acceptable, but you should consider the resulting loss in water capacity.

 

CARTRIDGE FLOW RATE (USGPM) VS. VISCOSITY DATA
FOR 2 PSI AND 5 PSI INITIAL PRESSURE DROPS

 

CARTRIDGE
33 SUS
2 CS
39 SUS
4 CS
46 SUS
6 CS
59 SUS
10 CS
98 SUS
20 CS
142 SUS
30 CS
187 SUS
40 CS
CAP
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
AC-21005
240
20
20
11
20
7
18
4
11
2
5
1
4
1
3
AC-405SP
150
13
13
6
13
4
11
3
7
1
3
1
2
1
2
AC-409SP
240
20
20
11
20
7
18
4
11
2
5
1
4
1
3
AC-51205
980
50
50
45
50
31
50
18
46
9
23
6
15
5
12
AC-52405
1960
100
100
90
100
62
100
36
92
18
46
12
30
10
24
AC-61405
1270
50
50
50
50
37
50
22
50
11
28
7
18
6
14
AC-718P3
670
50
50
33
50
22
50
13
32
7
17
4
10
3
8
AC-7181/2
670
50
50
36
50
24
50
15
36
7
18
5
12
4
9
AC-71801
1850
50
50
36
50
24
50
15
36
7
18
5
12
4
9
AC-71805
1850
50
50
50
50
50
50
33
50
17
42
11
28
8
21
AD-21025
240
20
20
20
20
14
20
9
20
4
11
3
7
2
5
AD-51225
980
50
50
50
50
50
50
44
50
22
50
15
36
11
28
AD-52425
1960
100
100
100
100
100
100
88
100
44
100
30
72
22
56
AD-61425
1270
50
50
50
50
50
50
50
50
27
50
18
45
14
35
AD-71825
1850
50
50
50
50
50
50
50
50
41
50
27
50
20
50




CARTRIDGE
233 SUS
50 CS
348 SUS
75 CS
463 SUS
100 CS
927 SUS
200 CS
1390 SUS
300 CS
1853 SUS
400 CS
2316 SUS
500 CS
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
2 psi
5 psi
AC-21005
1
2
-
1
-
1
-
-
-
-
-
-
-
-
AC-405SP
-
1
-
1
-
-
-
-
-
-
-
-
-
-
AC-409SP
1
2
-
1
-
1
-
-
-
-
-
-
-
-
AC-51205
4
9
2
6
2
5
1
2
1
2
-
1
-
1
AC-52405
8
18
4
12
4
10
2
4
2
4
1
2
1
2
AC-61405
5
11
3
7
2
6
1
3
1
2
-
1
-
1
AC-718P3
3
7
2
5
1
3
-
1
-
1
-
-
-
-
AC-7181/2
3
7
2
5
1
4
1
2
-
1
-
1
-
-
AC-71801
3
7
2
5
1
4
1
2
-
1
-
1
-
-
AC-71805
7
17
4
11
3
8
2
4
1
3
1
2
1
2
AD-21025
2
4
1
3
1
2
-
1
-
1
-
-
-
-
AD-51225
9
22
6
15
4
11
2
5
1
4
1
3
1
2
AD-52425
18
44
12
30
8
22
4
10
2
8
2
6
2
4
AD-61425
11
27
7
18
5
13
3
7
2
5
1
3
1
2
AD-71825
16
40
11
27
8
20
4
10
3
7
2
5
2
4

NOTES:

  1. Figures in table are flow rates (USGPM) that will cause a pressure drop of 2 or 5 psi across the cartridge.
  2. “CAP” is the water holding capacity in milliliters for 33 SUS (2 CS) fuel at the flow rates shown. These flow rates are the generally recommended maximum values for the specific cartridges.

 

WATER HOLDING CAPACITY


Water capacity decreases when viscosity or flow rate increases. The graphs below show typical characteristics. For any specific application you must trade off between capacity (how much water the cartridge will hold before it must be changed) and flow rate (size of filter housing and initial cost). For long term operating cost benefits, it is always best to use a larger housing (reduce the flow rate per cartridge).

WATER CAPACITY AS A FUNCTION OF VISCOSITY AND FLOW RATE
AC-52405, AD-52425, AC-71801, AC-71805, and AD-71825 CARTRIDGES

 

WATER CAPACITY AS A FUNCTION OF VISCOSITY AND FLOW RATE
AC-51205, AD-51225, AC-718P3, and AC-7181/2 CARTRIDGES

 

 

Filter Sizing Information AC and AD Series Aquacon® Cartridges - Data Sheet #1709