Cold Trap - LNT830

 
 

Cold Trap
LNT830

Designed for Transformer Dry-outs

 

DESCRIPTION

 

The measurement of water removal during a hot oil transformer dry-out is essential to evaluate the effectiveness and progress of the process. The LNT830 is a stand-alone device that causes moisture in the vacuum line to be trapped and accumulated for measurement. The unit can be installed anywhere between the transformer and the vacuum processing system. The secondary benefit in removing the moisture from the vacuum line is that it allows lower vacuum levels to be achieved and it keeps the vacuum pump oil dry.

The LNT830 has no moving parts so it is a completely reliable system for trapping water vapor. Cool down of the chamber is instantaneous when liquid nitrogen is added. There is no waiting for the temperature to drop as with refrigeration operated cold traps. A vacuum tight sight glass tells the operator when ice has formed and the unit requires thawing. A built-in bypass allows uninterrupted operation and servicing.

 

FEATURES

  • Low cost when compared to refrigeration-type cold traps
  • 100% reliable operation, no moving parts
  • Simple operation, just install and fill with liquid nitrogen
  • Large 3 1/2 gallon ice capacity
  • Bypass valve to prevent interruption of the drying process while de-frosting
  • Large liquid nitrogen capacity - 1.75 gallons
  • Standard 3" ASA companion flanges included
  • OK up to 800 CFM

 

WEIGHTS AND DIMENSIONS


Length: 45-5/8” flange to flange
Height: 22-3/4” to top of valve
Depth: 18”
Bottom to pipe centerline: 12”
Diameter of chamber top flange: 12”
Weight: 300 pounds

 

LNT830 Cold Trap Data Sheet #1844

 
     